capability, use the MU command at the ENTER NEXT COMMAND prompt and
go to page for Change Device.
5. Verify the LANCNC-FAD device matches the baud rate expected. The
LANCNC.INI file sets the baud rate on the device. Otherwise, 38,400 is the
default.
6. The LANCNC-FAD command set requires a plus to be used instead of the enter
key. After entering a command, end the command with a plus and do not press the
enter key or return key.
7. The CD,10 and CD,8 commands are CNC commands, not “plus” commands for
the LANCNC-FAD device. Press the enter key after the CD commands, do not
press a plus key at the end of the commands.
Problem: The CNC gives an error that the command is not recognized.
1. The LANCNC-FAD command set requires a plus to be used instead of the enter
key. After entering a command, end the command with a plus and do not press the
enter key or return key.
2. The CD,10 and CD,8 commands are commands for the CNC and not the
LANCNC-FAD. Press the enter key after the CD commands. Do not press a plus
key at the end of CD commands.
Problem: Program stops for no apparent reason when using DNC mode.
1. Use the DNCX X-modem feature if available on the Fadal.
2. Certain Fadal versions require comment block lines to have an N word on the
comment line. If they do not have the N word, the CNC will give an error. Delete
the comments or add N words to the comment lines. The same comment line can
be used if desired. The LANCNC dynamically adds an N1 before a comment
character. The comment character must be the first character in the line.
Problem: Part of the file is missing.
1. When using a PC, always use the “Safely remove hardware” icon before
removing the SD card from a computer.
2. On the LANCNC-FAD device, wait for the file to be completely saved after
punching.
3. There is not enough room on the SD card to save the file completely.
- 21 -